I would like to know why and when house wiring in the U.S...

<< Back to: Electrical Wiring FAQ (Part 1 of 2)

Question by Larry
Submitted on 7/18/2003
Related FAQ: Electrical Wiring FAQ (Part 1 of 2)
Rating: Rate this question: Vote
I would like to know why and when house wiring in the U.S went from 2 wire duplex outlets to 3 wire duplex outlets?


Answer by SHAUN31
Submitted on 11/20/2003
Rating:  Rate this answer: Vote
YEARS AGO THEY DIDN'T USE A GROUND WIRE. NOW WE USE 14/2 WITH GROUND FOR MOST HOUSE WIRING AND USUALLY USE 14/2 WITH GROUND FOR LONGER RUNS OR MORE LOAD. IF A LONG DISTANCE LIKE TO A GARAGE DETACHED USE A 10/2 WITH GROUND. IT IS REALLY STILL TWO WIRES----A WHITE (NEUTRAL) AND A BLACK (HOT) ONLY WITH THE GROUND COPPER WIRE ALONG WITH THOSE MAKING IT 3 WIRES. THATS WHY THEY CALL IT 3 WIRE OR 14/2WIRE WITH GROUND. GLAD TO HELP

 

Answer by msj520
Submitted on 2/19/2004
Rating:  Rate this answer: Vote
++vkkkkkkkkh hl

 

Answer by mister switch
Submitted on 5/24/2005
Rating: Not yet rated Rate this answer: Vote
14/2 romex is used for loads 15 amps or less because it has a ground it is not considered 3 wire romex three wire romex has
two current carrying conductors and a netural and a ground wire is rated in amps  match wire size with the load it is serving example 12/2 wg 20 amps 10/2 wg 30 amps long runs you need to concider voltage drop some instances you can go to the next size  wire depending on the current load

 

Your answer will be published for anyone to see and rate.  Your answer will not be displayed immediately.  If you'd like to get expert points and benefit from positive ratings, please create a new account or login into an existing account below.


Your name or nickname:
If you'd like to create a new account or access your existing account, put in your password here:
Your answer:

FAQS.ORG reserves the right to edit your answer as to improve its clarity.  By submitting your answer you authorize FAQS.ORG to publish your answer on the WWW without any restrictions. You agree to hold harmless and indemnify FAQS.ORG against any claims, costs, or damages resulting from publishing your answer.

 

FAQS.ORG makes no guarantees as to the accuracy of the posts. Each post is the personal opinion of the poster. These posts are not intended to substitute for medical, tax, legal, investment, accounting, or other professional advice. FAQS.ORG does not endorse any opinion or any product or service mentioned mentioned in these posts.

 

<< Back to: Electrical Wiring FAQ (Part 1 of 2)


[ Home  |  FAQ-Related Q&As  |  General Q&As  |  Answered Questions ]

© 2008 FAQS.ORG. All rights reserved.