Top Document: Data Communications Cabling FAQ Previous Document: 4.0 Not Used (Blank) Next Document: 6.0 Cable Conductors See reader questions & answers on this topic! - Help others by sharing your knowledge CMS, CL2X (Restricted Cable) must be enclosed in conduit, up to 10 feet exposed; must pass UL 1581 VW-1 test CM, CL2 (General Purpose Cable) for use in areas other than risers or plenums; must pass UL 1581 vertical tray test CMR, CL2R (Riser Cable) for cable in vertical shafts; must pass UL test method 1666 CMP, CL2P (Plenum Cable) for use in plenum areas (air ducts); must pass UL 910 test for smoke and flame spread User Contributions:Top Document: Data Communications Cabling FAQ Previous Document: 4.0 Not Used (Blank) Next Document: 6.0 Cable Conductors Single Page [ Usenet FAQs | Web FAQs | Documents | RFC Index ] Send corrections/additions to the FAQ Maintainer: pmac@fox.nstn.ca (Peter Macaulay)